Butadiene PVC Compound Soft Cable
Http://www.ahzdh.com Time: 11/10/10 10:33
It is used for supervising and controlling return circuit of A.C. rated voltage of 450/750V or lower, power connection of various mobile electrical equipments, radio devices, and lighting & protection under low temperature.
Executive standard: enterprise standard and JB1170-75 standard
Working condition
- Long-term working temperature of wire conductor is no more than 180℃ for cable with silicon insulation, 70℃ for that with PVC insulation
- Min. environment temperature of wire is -40℃
- Bending radius allowed by wire is no less than 8 times that of cable O.D OR 6 times for cable with soft structure.
Type and Description
Type |
Cable description |
Note |
YVFR |
Soft power cable with Cu core, butadiene PVC insulation and sheath |
If thin-plated copper wire braided shielding is needed, the letter “P” in the original type of cable shall be changed into the letter “P1”.
|
YVFB |
Flat type soft power cable with Cu core, butadiene PVC insulation and sheath |
|
YGVFB |
Flat type soft power cable with Cu core, silicon rubber insulation and butadiene PVC sheath |
|
KVFR |
Soft control cable with Cu core, butadiene PVC insulation and sheath |
|
KVFRP |
Soft control cable with Cu core, butadiene PVC insulation and sheath, copper wire braided shielding |
|
KVFB |
Flat type soft control cable with Cu core, butadiene PVC insulation and sheath |
|
KGVFB |
Flat type soft control cable with Cu core, silicon rubber insulation and butadiene PVC sheath |
Main Technical Parameter
- Max. DC resistance of conductor at 20℃ shall meet the requirement of the following table
Nominal cross section area (mm2) |
Conductor structure |
Conductor DC resistance at 20℃≤Ω/km |
|
Not tinned |
tinned |
||
0.5 |
16/0.20 |
39.0 |
40.1 |
0.75 |
24/0.20 |
26.0 |
26.7 |
1.0 |
32/0.20 |
19.5 |
20.0 |
1.5 |
30/0.25 |
13.3 |
13.7 |
2.5 |
49/0.26 |
7.98 |
8.21 |
4 |
56/0.30 |
4.95 |
5.09 |
6 |
84/0.30 |
3.30 |
3.39 |
10 |
84/0.40 |
1.91 |
1.95 |
16 |
110/0.43 |
1.21 |
1.24 |
25 |
170/0.43 |
0.78 |
0.795 |
35 |
240/0.43 |
0.554 |
0.565 |
50 |
342/0.43 |
0.386 |
0.393 |
70 |
482/0.43 |
0.272 |
0.277 |
95 |
654/0.43 |
0.206 |
0.210 |
120 |
827/0.43 |
0.161 |
0.164 |
150 |
1033/0.43 |
0.129 |
0.132 |
185 |
1274/0.43 |
0.106 |
0.108 |
- Finished control cable shall bear A.C. test voltage of 3000V under power frequency for 5 min without puncture of insulation
- Finished power cable shall bear A.C. test voltage of 3500V under power frequency for without puncture of insulation
Copyright © 2009-2011 Anhui Electric (Group) Shares Co., Ltd.