TK8000-Ex Isolated Barrier on Operating Side
Http://www.ahzdh.com Time: 11/20/10 08:27

General Description
TK8000-Ex Isolated Barrier on Operating Side,transmits the 4 ~ 20mA signal of regulators (operator) to the actuator after isolation, and limit dangerous energy fleeing from the safe side into a dangerous place.
Main technical parameters
Explosion-proof marker: [Exib]ⅡC
Power Consumption: about 3W(24V power supply, when the output is 20mA)
The Danger Zone Output:4~20mADC actuator supply
The Safety Zone Input:4~20mA DC
TK8000-Ex,TK8000-Ex(V)
Signal:4~20mA,1~5V
Output Load:100~650Ω,250Ω(内部)
Output Accuracy: 0.1% F.S
Temperature drift: 0.01% F.S/℃
Continuous operating temperature: -20~+60℃
Certified by China National Quality Supervision and Test Center for Explosion Protected Electrical Products(CQST) (between terminals 9 and 10)
Uo≤30V,Io≤26mA,Co≤0.4μF,Lo≤1mH,Po≤0.78Um=250VDC/AC
Applying to field devices
4 ~ 20mA Dc current signal
Instrument selection
Type |
Input Signal |
Output Signal |
Channels |
|
TK8041-Ex |
4~20mA DC |
4~20mA DC/1~5V DC |
Single |
|
TK8042-Ex |
4~20mA DC |
4~20mA DC/1~5V DC |
Double |
Copyright © 2009-2011 Anhui Electric (Group) Shares Co., Ltd.
